Ramsey Electronics QRP-80 Instruction Manual Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 19
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
QAMP-80 • 12
end with solder all the way up to the core body. This winding is the 2
turn center-tapped primary of T1.
47. Locate the smaller transformer (T2) and install it snugly on the PC
board.
48. Install the larger transformer (T1) into the indicated location on the PC
board.
49. Install L1, a 25 turn toroid inductor wound previously. If desired, a small
dab of hot melt glue, bathtub sealer, or caulk may be used to secure the
toroids.
50. Install L2, the 28 turn toroid inductor - you marked it special,
remember?
51. Install L3, the remaining 25 turn toroid inductor.
This completes the assembly of your QRP power amplifier. Now's a good time
to give your masterpiece a good going over, being especially alert for any:
bridged-over solder joints;
misplaced components;
transistors or diodes placed wrong;
electrolytic capacitors installed wrong.
INITIAL TESTS:
To prepare your amplifier for testing you'll need the following:
1. Multimeter capable of measuring voltage and current.
2. 12 volt DC power source of at least 3 amp capacity.
3. Suitable dummy load and resonant antenna.
4. QRP transmitter with a power output in the ½ to 2 watt range,
such as the Ramsey QRP-80.
5. Proper cables to interface between the QRP transmitter and the
Page view 11